Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : ATOS
Model Number : SDKE-1713 10S SDKE-1751/2 10S SDKE-1711 10S SDKE-1715 10S SDKE-1710 10S SDKE-1716 10S SDKE-1714 10S
Place of Origin : ITALY CHINA
MOQ : 1
Price : 45-168USD
Payment Terms : T/T, Western Union, MoneyGram,Paypal
Supply Ability : 500 pcs per week
Delivery Time : 3-12working days
Packaging Details : poly bags, box, cartons, pallets
Max Pressure : 35Mpa
Allowable Tank Port Back Pressure : 20. 6MPa
Coil type : D24:DC24V A24:AC24V A11: AC110V A38:AC380V RA1:AC110V RA2:AC220V D12: DC12V A22:AC220V
Terminations : DG: DIN43650 DL: Lead wires(2)
Insulation Class : H 180℃
Voltage : 90 %V at rated voltage
Power Consumption : DC 28-31W AC: 19-26W
Fluids-Temperatures : -40-120℃
Mounting surface : ISO 4401 size 10
Protection degree to DIN EN 60529 : IP65
Assembly position / location | Any position for all valves except for type- 170* (without springs) that must be instaed with hori- zontal axis if operated by impulses | ||
Subplate surface finishing | Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101) | ||
MTTFd values according to EN ISO 13849 | 150 years, for further details see technical table P007 | ||
Ambient temperature | Standard execution = -30°C +70°C /PE option = -20°C-+ 70°C /BT option = -40°C- +70°C | ||
Seals, recommended fluid temperature | NBR seals (standard) = -20C + +80*C, with HFC hydraulic fluids = -20*C +50C FKM seals (/PE option)= -20°C + +80C HNBR seals (/BT option)= -40°C - +60°C, with HFC hydraulic fluids= -40°C to +50°C | ||
Recommended viscosity | 15-100 mm2/s - max allowed range 2.8 + 500 mm2/s | ||
Max fluid contamination level | IS04406 class 20/18/15 NAS1638 class 9, see also fliter section at www.atos .com or KTF Ccatalog | ||
Hydraulic fluid | Suitable seals type | Classification | Ref. Standard |
Mineral oils | NBR, FKM, HNBR | HL, HLP, HLPD, HVLP, HVLPD | DIN 51524 |
Flame resistant without water | FKM | HFDU, HFDR | ISO 12922 |
Flame resistant with water | NBR, HNBR | HFC | |
Flow direction | As shown in the symbols of table | ||
Operating pressure | Ports P ,A,B: 350 bar; Port T210 bar for DC version (250 bar with option M); 160 bar for AC version | ||
Rated flow | See diagrams Q/Ap at section | ||
Maximum flow | 150 l/min, see operating limits at section |
![]() |
ATOS Direct Operated Double Solenoid Directional Valves SDKE-1711 10S SDKE-1716 10S Images |